Biamp VOCIA LSI-16 Spécifications

Naviguer en ligne ou télécharger Spécifications pour Mise en réseau Biamp VOCIA LSI-16. Biamp VOCIA LSI-16 Specifications Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 16
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Biamp Systems, 10074 S.W. Arctic Drive, Beaverton, Oregon 97005 U.S.A. (503) 641-7287 www.biamp.com
Vocia
®
LSI-16
Operation Manual
Vue de la page 0
1 2 3 4 5 6 ... 15 16

Résumé du contenu

Page 1 - Operation Manual

Biamp Systems, 10074 S.W. Arctic Drive, Beaverton, Oregon 97005 U.S.A. (503) 641-7287 www.biamp.comVocia®LSI-16Operation Manual

Page 2

10LSI-16 REAR PANELControl InputsTwo ve-position plug-in barrier strip connectors provide control input connections. Eight separate channels plus two

Page 3

11LSI-16 REAR PANELOption SlotThe option slot allows for additional modules if required by the system design. A typical option module in this slot may

Page 4 - LSI-16 FRONT PANEL

12LSI-16 INSTALLATIONInstallationThe LSI-16 requires one 1.75 inches (44.45mm) high and 19 inches (483mm) wide rack space with 10 inches (254mm) depth

Page 5

13LSI-16 SPECIFICATIONSLife Safety Interface 16 SPECIFICATIONSSystem Fault Relay: Type: Load: Maximum operating voltage:Maximum operating c

Page 6

14LSI-16 WARRANTYBIAMP SYSTEMS IS PLEASED TO EXTEND THE FOLLOWING 5-YEAR LIMITED WARRANTY TO THE ORIGINAL PURCHASER OF THE PROFESSIONAL SOUND EQUIPMEN

Page 7

15COMPLIANCE

Page 8

16COMPLIANCE

Page 9

2TABLE OF CONTENTSVOCIA LIFE SAFETY INTERFACE 16 (LSI-16) FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3FRONT PANEL . . . . .

Page 10 - LSI-16 REAR PANEL

3VOCIA LIFE SAFETY INTERFACE 16 (LSI-16)The LSI-16 is a networked device that serves as an interface between a Vocia system and emergency or re alarm

Page 11

4LSI-16 FRONT PANELSetup and UseThe Vocia software provides an intuitive interface for conguration and programming of the LSI-16. The information sup

Page 12 - LSI-16 INSTALLATION

5LSI-16 FRONT PANEL(LED 7) System Fault (continued)Because it indicates a potentially serious condition, the presence of a System Fault extinguishes i

Page 13 - LSI-16 SPECIFICATIONS

6LSI-16 REAR PANELDevice IDThe rotary ID switches are located on the back of the LSI-16 and give the unit a unique Device ID. The switches are in hexa

Page 14 - LSI-16 WARRANTY

7LSI-16 REAR PANELThis connection carries control data and power over a single Ethernet cable. The maximum distance between any unit and an Ethernet s

Page 15 - COMPLIANCE

8LSI-16 REAR PANELMonitored OutputsTwo black ve-position connectors are located next to the rotary switches. These are predominantly used for Monitor

Page 16

9LSI-16 REAR PANELSystem TestA system test can be initiated by simultaneously connecting monitored outputs 1 and 2 to ground (see connection diagram).

Commentaires sur ces manuels

Pas de commentaire